This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited.

Abstract

This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in TCP/IP- based internets. In particular, it defines objects for managing Frame Relay interfaces on DTEs.

The SNMPv2 Network Management Framework

The major components of the SNMPv2 Network Management framework are described in the documents listed below.

o RFC 1902 [1] defines the Structure of Management

    Information (SMI), the mechanisms used for describing and
    naming objects for the purpose of management.

o STD 17, RFC 1213 [2] defines MIB-II, the core set of

    managed objects (MO) for the Internet suite of protocols.

o RFC 1905 [3] defines the protocol used for network access

    to managed objects.

The framework is adaptable/extensible by defining new MIBs to suit the requirements of specific applications/protocols/situations.

Managed objects are accessed via a virtual information store, the MIB. Objects in the MIB are defined using the subset of Abstract Syntax Notation One (ASN.1) defined in the SMI. In particular, each object type is named by an OBJECT IDENTIFIER, which is an administratively assigned name. The object type together with an object instance serves to uniquely identify a specific instantiation of the object. For human convenience, often a textual string, termed the descriptor, is used to refer to the object type.

Overview

Frame Relay Operational Model

For the purposes of understanding this document, Frame Relay is viewed as a multi-access media, not as a group of point- to-point connections. This model proposes that Frame Relay is a single interface to the network (physical connection) with many destinations or neighbors (virtual connections). This view enables a network manager the ability to group all virtual connections with their corresponding physical connection thereby allowing simpler diagnostics and trouble shooting.

With the extension of the interfaces MIB, it is possible to configure frame relay DLCs as individual interfaces and create ifTable entries for each. This is not recommended and is not directly supported by this MIB. Additionally, in the presence of demand circuits creation of individual ifEntries for each is not possible.

Should the user wish to group DLCs together to associate them with a higher layer, or to associate a DLC with an unnumbered point-to-point service, the frame relay DTE MIB provides an entry in the frCircuitEntry record. For example, suppose one were to configure a company proprietary protocol to run above several of the frame relay VCs. The basic layering would look something like the following:

  IP (ipaddrEntry 1 )  IP (ipaddrEntry 2)  IP (ipaddrEntry 3)
     |                    |                     |
     |                    |                     |
     |                    |              proprietary protocol
     |                    |              layer   (ifIndex 3)
     |                    |                     |
     |                    |                     |
  DLCI 20            DLCI 30            DLCI 40/41/42
  (ifIndex 2)        (ifIndex 2)         (ifIndex 2,
                                          logical ifIndex 3)
     |                    |                     |
     |                    |                     |
     |____________________|_____________________|
                          |
                          |
                  FR  DLMCI (ifIndex.2)
                          |
                          |
               Physical Interface (ifIndex.1)

A configuration which specified that DLCI 40, 41,and 42 were associated with a proprietary protocol layer, while DLCI 20 and 30 were to run IP directly can now be expressed using a combination of frCircuitIfIndex and frCircuitLogicalIfIndex. In this particular case DLCIs 40, 41 and 42 would use frCircuitIfIndex equal to the frame relay interface level (2) while their frCircuitLogicalIfIndex would indicate the proprietary protocol (3). DLCIs 20 and 30 would have both instances set to the frame relay interface (2).

  Object           Meaning for Frame Relay Interface
  ______           _____________________________________
  ifDescr          As per DESCRIPTION in RFC 1573.
  ifType           The value allocated for Frame Relay
                   Interfaces - frameRelay (32).
  ifMtu            Set to maximum frame size in octets for
                   this frame relay interface.
  ifSpeed          The access rate for the frame relay
                   interface.  This could be different from
                   the speed of the underlying physical
                   interface, e.g. in a fractional T1 case
                   the access rate could be 384 kbits/s (the
                   value reported in this object) whereas the
                   speed of the underlying interface would be
                   1.544 Mbits/s (the value reported in the
                   instance of ifSpeed for the ifEntry with
                   type ds1).
  ifPhysAddress    The primary address for this interface
                   assigned by the Frame Relay interface
                   provider.  An octet string of zero length
                   if no address is used for this interface.
  ifAdminStatus    As per DESCRIPTION in RFC 1573.
  ifOperStatus     As per DESCRIPTION in RFC 1573.
  ifLastChange     As per DESCRIPTION in RFC 1573.
  ifInOctets       The number of received octets.  This
                   includes not only the information field
                   (user data) but also the frame relay header
                   and CRC.
  ifInUcastPkts    The number of frames received on non-
                   multicast DLCIs
  ifInDiscards     The number of frames that were successfully
                   received but were discarded because of
                   format errors or because the VC was not
                   known.  Format errors, in this case, are
                   any errors which would prevent the system
                   from recognizing the DLCI and placing the
                   error in the frCircuitDiscard category.
  ifInErrors       The number of received frames that are
                   discarded, because of an error.
                   Possible errors can be the following: the
                   frame relay frames were too long or were
                   too short, the frames had an invalid or
                   unrecognized DLCI values, or incorrect
                   header values.
  ifInUnknownProtos  Number of unknown or unsupported
                   upper layer protocol frames received
                   and discarded.
  ifOutOctets      The number of received octets.  This
                   includes not only the information field
                   (user data) but also the frame relay header
                   and CRC.
  ifOutUcastpkts   The number of frames sent.
  ifOutDiscards    The number of frames discarded in the
                   transmit direction.
  ifOutErrors      The number of frames discarded in the
                   egress direction, because of errors.
  ifName           As per DESCRIPTION in RFC 1573.
  ifInMulticastPkts   The number of unerrored frames received
                      on a multicast DLCI.
  ifInBroadcastPkts   Always zero (0) as there are no broadcast
                      frames.
  ifOutMulticastPkts  The number of frames transmitted over a
                      multicast DLCI.
  ifOutBroadcastPkts  Always zero (0) as there are no broadcast
                      frames.
  ifHCInOctets     Only required when ifSpeed >= 155 Mbits/s.
 See
                   details for ifInOctets.
  ifHCOutOctets    Only required when ifSpeed >= 155 Mbits/s.
 See
                   details for ifInOctets.
  ifLinkUpDownTrapEnble  As per DESCRIPTION in RFC 1573.
  ifHighSpeed      The access rate of the frame relay interface
                   measured in Mbits/s.  If the access rate is
                   less than 1 Mbits/s, this object returns 0.
  ifPromiscuousMode   Set to false(2).
  ifConnectorPresent  Set to false(2).

Textual Conventions

One new data type is introduced as a textual convention in this MIB document. This textual convention enhances the readability of the specification and can ease comparison with other specifications if appropriate. It should be noted that the introduction of this textual conventions has no effect on either the syntax nor the semantics of any managed objects. The use of this is merely an artifact of the explanatory method used. Objects defined in terms of one of these methods are always encoded by means of the rules that define the primitive type. Hence, no changes to the SMI or the SNMP are necessary to accommodate this textual conventions which is adopted merely for the convenience of readers and writers in pursuit of the elusive goal of clear, concise, and unambiguous MIB documents.

The new data type is DLCI. DLCI refers to the range 0..DLCINumber, and is used to refer to the valid Data Link Connection Indices. DLCINumber is, by definition, the largest possible DLCI value possible under the configured Q.922 Address Format.

Structure of MIB

The MIB is composed of three groups, one defining the Data Link Connection Management Interface (DLCMI), one describing the Circuits, and a third describing errors.

During normal operation, Frame Relay virtual circuits will be added, deleted and change availability. The occurrence of such changes is of interest to the network manager and therefore, one trap is defined, intended to be corollary to the SNMP "Link Up" and "Link Down" traps.

Changes from RFC 1315

Below are listed the changes from the previously published version this document, which was RFC 1315:

o The MIB module was converted from SMIv1 to SMIv2 format.

    Note: due to this, the table indices have access of
    "read-only" instead of "not-accessible", which is the
    typical value for index objects in SMIv2.

o The module name was changed from RFC1315-MIB to FRAME-

    RELAY-DTE-MIB.

o The textual convention "Index" was dropped from the MIB

    module and "InterfaceIndex" from the interfaces MIB
    module, IF-MIB, was used in its place.

o Objects frDlcmiStatus and frDlcmiRowStatus were added to

    table frDlcmiTable.

o Added values "itut933A(5)" (from CCITT Q933 Annex A) and

    "ansiT1617D1994(6)" (from ANSI T1.617a-1994 Annex D) to
    the enumerations for object frDlcmiState.

o The labels for the enumerated values for object

    frDlcmiAddressLen were renamed to remove their hyphens as
    required by SMIv2.

o Added clarification that the "management virtual circuit"

    (i.e. DLCI 0) is a member of the circuit table.

o Added the following objects to table frCircuitTable:

    frCircuitMulticast, frCircuitType, frCircuitDiscards,
    frCircuitReceivedDEs, frCircuitSentDEs,
    frCircuitLogicalIfIndex, and  frCircuitRowStatus.

o The definition of object frCircuitReceivedOctets was

    clarified as to which octets were counted.

o Added the objects frErrFaults and frErrFaultTime to table

    frErrTable.

o Added clarification to the values of object frErrType.

o Added size on definition of object frErrData and

    clarified what data to capture.

o Changed identififier for OID value { frameDelayDTE 4 }

    from frame-relay-globals to frameRelayTrapControl.

o Added object frTrapMaxRate.

o Created object groups frPortGroup, frCircuitGroup,

    frTrapGroup, frErrGroup, frPortGroup0, frCircuitGroup0,
    frTrapGroup0, and frErrGroup0.

o Created notification group frNotificationGroup.

o Created module compliances frCompliance and

    frCompliance0.

o Added ranges to objects frCircuitCommittedBurst,

    frCircuitExcessBurst, and frCircuitThroughput.

Definitions

 FRAME-RELAY-DTE-MIB DEFINITIONS ::= BEGIN
 IMPORTS
             MODULE-IDENTITY, OBJECT-TYPE, Counter32,
             Integer32, NOTIFICATION-TYPE            FROM SNMPv2-SMI
             TEXTUAL-CONVENTION, RowStatus, TimeStamp FROM SNMPv2-TC
             MODULE-COMPLIANCE, OBJECT-GROUP,
             NOTIFICATION-GROUP                     FROM SNMPv2-CONF
             transmission                           FROM RFC1213-MIB
             InterfaceIndex                           FROM IF-MIB;
 --  Frame Relay DTE MIB
 frameRelayDTE MODULE-IDENTITY
     LAST-UPDATED "9705010229Z" -- Thu May  1 02:29:46 PDT 1997
     ORGANIZATION "IETF IPLPDN Working Group"
     CONTACT-INFO
        "       Caralyn Brown
        Postal: Cadia Networks, Inc.
                1 Corporate Drive
                Andover, Massachusetts  01810
        Tel:    +1 508 689 2400 x133
        E-Mail: [email protected]
                Fred Baker
        Postal: Cisco Systems
                519 Lado Drive
                Santa Barbara, California 93111
        Tel:    +1 408 526 425
        E-Mail: [email protected]"
     DESCRIPTION
        "The MIB module to describe the use of a Frame Relay
        interface by a DTE."
     REVISION "9705010229Z" -- Thu May  1 02:29:46 PDT 1997
     DESCRIPTION
        "Converted from SMIv1 to SMIv2. (Thus, indices are
        read-only rather than being not-accessible.) Added
        objects and made clarifications based on implementation
        experience."
     REVISION "9204010000Z"
     DESCRIPTION
        "Published as RFC 1315, the initial version of this MIB
        module."
     ::= { transmission 32 }
 --
 --      the range of a Data Link Connection Identifier
 --
 DLCI ::= TEXTUAL-CONVENTION
     STATUS      current
     DESCRIPTION
        "The range of DLCI values.  Note that this varies by
        interface configuration; normally, interfaces may use
        0..1023, but may be configured to use ranges as large
        as 0..2^23."
     SYNTAX      Integer32(0..8388607)
 --
 --  Data Link Connection Management Interface
 --      The variables that configure the DLC Management Interface.
 frDlcmiTable OBJECT-TYPE
     SYNTAX   SEQUENCE OF FrDlcmiEntry
     MAX-ACCESS   not-accessible
     STATUS   current
     DESCRIPTION
        "The Parameters for the Data Link Connection Management
        Interface for the frame relay service on this
        interface."
     REFERENCE
        "American National Standard T1.617-1991, Annex D"
     ::= { frameRelayDTE 1 }
 frDlcmiEntry OBJECT-TYPE
     SYNTAX   FrDlcmiEntry
     MAX-ACCESS   not-accessible
     STATUS   current
     DESCRIPTION
        "The Parameters for a particular Data Link Connection
        Management Interface."
     INDEX { frDlcmiIfIndex }
     ::= { frDlcmiTable 1 }
 FrDlcmiEntry ::=
     SEQUENCE {
         frDlcmiIfIndex                  InterfaceIndex,
         frDlcmiState                    INTEGER,
         frDlcmiAddress                  INTEGER,
         frDlcmiAddressLen               INTEGER,
         frDlcmiPollingInterval          Integer32,
         frDlcmiFullEnquiryInterval      Integer32,
         frDlcmiErrorThreshold           Integer32,
         frDlcmiMonitoredEvents          Integer32,
         frDlcmiMaxSupportedVCs          DLCI,
         frDlcmiMulticast                INTEGER,
         frDlcmiStatus                   INTEGER,
         frDlcmiRowStatus                RowStatus
 }
 frDlcmiIfIndex OBJECT-TYPE
     SYNTAX   InterfaceIndex
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "The ifIndex value of the corresponding ifEntry."
     ::= { frDlcmiEntry 1 }
 frDlcmiState OBJECT-TYPE
     SYNTAX INTEGER      {
         noLmiConfigured (1),
         lmiRev1         (2),
         ansiT1617D      (3),  -- ANSI T1.617 Annex D
         ansiT1617B      (4),  -- ANSI T1.617 Annex B
         itut933A        (5),  -- CCITT Q933 Annex A
         ansiT1617D1994  (6)   -- ANSI T1.617a-1994 Annex D
     }
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "This variable states which Data Link Connection
        Management scheme is active (and by implication, what
        DLCI it uses) on the Frame Relay interface."
     REFERENCE
        "American National Standard T1.617-1991, American
        National Standard T1.617a-1994, ITU-T Recommendation
        Q.933 (03/93)."
     ::= { frDlcmiEntry 2 }
 frDlcmiAddress OBJECT-TYPE
     SYNTAX      INTEGER {
                 q921           (1),  -- 13 bit DLCI
                 q922March90    (2),  -- 11 bit DLCI
                 q922November90 (3),  -- 10 bit DLCI
                 q922           (4)   -- Final Standard
     }
     MAX-ACCESS  read-create
     STATUS  current
     DESCRIPTION
        "This variable states which address format is in use on
        the Frame Relay interface."
     ::= { frDlcmiEntry 3 }
 frDlcmiAddressLen OBJECT-TYPE
     SYNTAX  INTEGER     {
             twoOctets (2),
             threeOctets (3),
             fourOctets (4)
     }
     MAX-ACCESS  read-create
     STATUS  current
     DESCRIPTION
        "This variable states the address length in octets.  In
        the case of Q922 format, the length indicates the
        entire length of the address including the control
        portion."
     ::= { frDlcmiEntry 4 }
 frDlcmiPollingInterval OBJECT-TYPE
     SYNTAX   Integer32 (5..30)
     UNITS    "seconds"
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "This is the number of seconds between successive
        status enquiry messages."
     REFERENCE
        "American National Standard T1.617-1991, Section D.7
        Timer T391."
     DEFVAL { 10 }
     ::= { frDlcmiEntry 5 }
 frDlcmiFullEnquiryInterval OBJECT-TYPE
     SYNTAX   Integer32 (1..255)
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "Number of status enquiry intervals that pass before
        issuance of a full status enquiry message."
     REFERENCE
        "American National Standard T1.617-1991, Section D.7
        Counter N391."
     DEFVAL { 6 }
     ::= { frDlcmiEntry 6 }
 frDlcmiErrorThreshold OBJECT-TYPE
     SYNTAX   Integer32 (1..10)
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "This is the maximum number of unanswered Status
        Enquiries the equipment shall accept before declaring
        the interface down."
     REFERENCE
        "American National Standard T1.617-1991, Section D.5.1
        Counter N392."
     DEFVAL { 3 }
     ::= { frDlcmiEntry 7 }
 frDlcmiMonitoredEvents OBJECT-TYPE
     SYNTAX   Integer32 (1..10)
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "This is the number of status polling intervals over
        which the error threshold is counted.  For example, if
        within 'MonitoredEvents' number of events the station
        receives 'ErrorThreshold' number of errors, the
        interface is marked as down."
     REFERENCE
        "American National Standard T1.617-1991, Section D.5.2
        Counter N393."
     DEFVAL { 4 }
     ::= { frDlcmiEntry 8 }
 frDlcmiMaxSupportedVCs OBJECT-TYPE
     SYNTAX   DLCI
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "The maximum number of Virtual Circuits allowed for
        this interface.  Usually dictated by the Frame Relay
        network.
        In response to a SET, if a value less than zero or
        higher than the agent's maximal capability is
        configured, the agent should respond badValue"
     ::= { frDlcmiEntry 9 }
 frDlcmiMulticast OBJECT-TYPE
     SYNTAX   INTEGER    {
                 nonBroadcast (1),
                 broadcast (2)
                 }
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "This indicates whether the Frame Relay interface is
        using a multicast service."
     ::= { frDlcmiEntry 10 }
 frDlcmiStatus OBJECT-TYPE
     SYNTAX   INTEGER    {
                 running      (1),    -- init complete, system running
                 fault        (2),    -- error threshold exceeded
                 initializing (3)     -- system start up
                 }
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "This indicates the status of the Frame Relay interface
        as determined by the performance of the dlcmi.  If no
        dlcmi is running, the Frame Relay interface will stay
        in the running state indefinitely."
     ::= { frDlcmiEntry 11 }
 frDlcmiRowStatus OBJECT-TYPE
     SYNTAX   RowStatus
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "SNMP Version 2 Row Status Variable.  Writable objects
        in the table may be written in any RowStatus state."
     ::= { frDlcmiEntry 12 }
 --
 -- A Frame Relay service is a multiplexing service.  Data
 -- Link Connection Identifiers enumerate virtual circuits
 -- (permanent or dynamic) which are layered onto the underlying
 -- circuit, represented by ifEntry.  Therefore, each of the entries
 -- in the Standard MIB's Interface Table with an IfType of
 -- Frame Relay represents a Q.922 interface.  Zero or more
 -- virtual circuits are layered onto this interface and provide
 -- interconnection with various remote destinations.
 -- Each such virtual circuit is represented by an entry in the
 -- circuit table.  The management virtual circuit (i.e. DLCI 0)
 -- is a virtual circuit by this definition and will be represented
 -- with an entry in the circuit table.
 --   Circuit Table
 -- The table describing the use of the DLCIs attached to
 -- each Frame Relay Interface.
 frCircuitTable OBJECT-TYPE
     SYNTAX   SEQUENCE OF FrCircuitEntry
     MAX-ACCESS   not-accessible
     STATUS   current
     DESCRIPTION
        "A table containing information about specific Data
        Link Connections (DLC) or virtual circuits."
     ::= { frameRelayDTE 2 }
 frCircuitEntry OBJECT-TYPE
     SYNTAX   FrCircuitEntry
     MAX-ACCESS   not-accessible
     STATUS   current
     DESCRIPTION
        "The information regarding a single Data Link
        Connection.  Discontinuities in the counters contained
        in this table are indicated by the value in
        frCircuitCreationTime."
     INDEX { frCircuitIfIndex, frCircuitDlci }
     ::= { frCircuitTable 1 }
 FrCircuitEntry ::=
     SEQUENCE {
         frCircuitIfIndex                InterfaceIndex,
         frCircuitDlci                   DLCI,
         frCircuitState                  INTEGER,
         frCircuitReceivedFECNs          Counter32,
         frCircuitReceivedBECNs          Counter32,
         frCircuitSentFrames             Counter32,
         frCircuitSentOctets             Counter32,
         frCircuitReceivedFrames         Counter32,
         frCircuitReceivedOctets         Counter32,
         frCircuitCreationTime           TimeStamp,
         frCircuitLastTimeChange         TimeStamp,
         frCircuitCommittedBurst         Integer32,
         frCircuitExcessBurst            Integer32,
         frCircuitThroughput             Integer32,
         frCircuitMulticast              INTEGER,
         frCircuitType                   INTEGER,
         frCircuitDiscards               Counter32,
         frCircuitReceivedDEs            Counter32,
         frCircuitSentDEs                Counter32,
         frCircuitLogicalIfIndex         InterfaceIndex,
         frCircuitRowStatus              RowStatus
 }
 frCircuitIfIndex OBJECT-TYPE
     SYNTAX   InterfaceIndex
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "The ifIndex Value of the ifEntry this virtual circuit
        is layered onto."
     ::= { frCircuitEntry 1 }
 frCircuitDlci OBJECT-TYPE
     SYNTAX   DLCI
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "The Data Link Connection Identifier for this virtual
        circuit."
     REFERENCE
        "American National Standard T1.618-1991, Section 3.3.6"
     ::= { frCircuitEntry 2 }
 frCircuitState OBJECT-TYPE
     SYNTAX   INTEGER    {
                 invalid (1),
                 active (2),
                 inactive (3)
              }
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "Indicates whether the particular virtual circuit is
        operational.  In the absence of a Data Link Connection
        Management Interface, virtual circuit entries (rows)
        may be created by setting virtual circuit state to
        'active', or deleted by changing Circuit state to
        'invalid'.
        Whether or not the row actually disappears is left to
        the implementation, so this object may actually read as
        'invalid' for some arbitrary length of time.  It is
        also legal to set the state of a virtual circuit to
        'inactive' to temporarily disable a given circuit.
        The use of 'invalid' is deprecated in this SNMP Version
        2 MIB, in favor of frCircuitRowStatus."
     DEFVAL { active }
     ::= { frCircuitEntry 3 }
 frCircuitReceivedFECNs OBJECT-TYPE
     SYNTAX   Counter32
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "Number of frames received from the network indicating
        forward congestion since the virtual circuit was
        created.  This occurs when the remote DTE sets the FECN
        flag, or when a switch in the network enqueues the
        frame to a trunk whose transmission queue is
        congested."
     REFERENCE
        "American National Standard T1.618-1991, Section 3.3.3"
     ::= { frCircuitEntry 4 }
 frCircuitReceivedBECNs OBJECT-TYPE
     SYNTAX   Counter32
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "Number of frames received from the network indicating
        backward congestion since the virtual circuit was
        created.  This occurs when the remote DTE sets the BECN
        flag, or when a switch in the network receives the
        frame from a trunk whose transmission queue is
        congested."
     REFERENCE
        "American National Standard T1.618-1991, Section 3.3.4"
     ::= { frCircuitEntry 5 }
 frCircuitSentFrames OBJECT-TYPE
     SYNTAX   Counter32
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "The number of frames sent from this virtual circuit
        since it was created."
     ::= { frCircuitEntry 6 }
 frCircuitSentOctets OBJECT-TYPE
     SYNTAX   Counter32
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "The number of octets sent from this virtual circuit
        since it was created.  Octets counted are the full
        frame relay header and the payload, but do not include
        the flag characters or CRC."
     ::= { frCircuitEntry 7 }
 frCircuitReceivedFrames OBJECT-TYPE
     SYNTAX   Counter32
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "Number of frames received over this virtual circuit
        since it was created."
     ::= { frCircuitEntry 8 }
 frCircuitReceivedOctets OBJECT-TYPE
     SYNTAX   Counter32
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "Number of octets received over this virtual circuit
        since it was created.  Octets counted include the full
        frame relay header, but do not include the flag
        characters or the CRC."
     ::= { frCircuitEntry 9 }
 frCircuitCreationTime OBJECT-TYPE
     SYNTAX   TimeStamp
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "The value of sysUpTime when the virtual circuit was
        created, whether by the Data Link Connection Management
        Interface or by a SetRequest."
     ::= { frCircuitEntry 10 }
 frCircuitLastTimeChange OBJECT-TYPE
     SYNTAX   TimeStamp
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "The value of sysUpTime when last there was a change in
        the virtual circuit state"
     ::= { frCircuitEntry 11 }
 frCircuitCommittedBurst OBJECT-TYPE
     SYNTAX   Integer32(0..2147483647)
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "This variable indicates the maximum amount of data, in
        bits, that the network agrees to transfer under normal
        conditions, during the measurement interval."
     REFERENCE
        "American National Standard T1.617-1991, Section
        6.5.19"
     DEFVAL   { 0 }  -- the default indicates no commitment
     ::= { frCircuitEntry 12 }
 frCircuitExcessBurst OBJECT-TYPE
     SYNTAX   Integer32(0..2147483647)
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "This variable indicates the maximum amount of
        uncommitted data bits that the network will attempt to
        deliver over the measurement interval.
        By default, if not configured when creating the entry,
        the Excess Information Burst Size is set to the value
        of ifSpeed."
     REFERENCE
        "American National Standard T1.617-1991, Section
        6.5.19"
     ::= { frCircuitEntry 13 }
 frCircuitThroughput OBJECT-TYPE
     SYNTAX   Integer32(0..2147483647)
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "Throughput is the average number of 'Frame Relay
        Information Field' bits transferred per second across a
        user network interface in one direction, measured over
        the measurement interval.
        If the configured committed burst rate and throughput
        are both non-zero, the measurement interval, T, is
            T=frCircuitCommittedBurst/frCircuitThroughput.
        If the configured committed burst rate and throughput
        are both zero, the measurement interval, T, is
                   T=frCircuitExcessBurst/ifSpeed."
     REFERENCE
        "American National Standard T1.617-1991, Section
        6.5.19"
     DEFVAL {0}  -- the default value of Throughput is
                 -- "no commitment".
     ::= { frCircuitEntry 14 }
 frCircuitMulticast OBJECT-TYPE
     SYNTAX   INTEGER    {
                 unicast   (1),
                 oneWay    (2),
                 twoWay    (3),
                 nWay      (4)
                 }
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "This indicates whether this VC is used as a unicast VC
        (i.e. not multicast) or the type of multicast service
        subscribed to"
     REFERENCE
        "Frame Relay PVC Multicast Service and Protocol
        Description Implementation: FRF.7 Frame Relay Forum
        Technical Committe October 21, 1994"
          DEFVAL {unicast}
                      -- the default value of frCircuitMulticast is
                      -- "unicast" (not a multicast VC).
          ::= { frCircuitEntry 15 }
 frCircuitType OBJECT-TYPE
     SYNTAX   INTEGER    {
                 static  (1),
                 dynamic (2)
              }
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "Indication of whether the VC was manually created
        (static), or dynamically created (dynamic) via the data
        link control management interface."
     ::= { frCircuitEntry 16 }
 frCircuitDiscards OBJECT-TYPE
     SYNTAX   Counter32
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "The number of inbound frames dropped because of format
        errors, or because the VC is inactive."
     ::= { frCircuitEntry 17 }
 frCircuitReceivedDEs OBJECT-TYPE
     SYNTAX   Counter32
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "Number of frames received from the network indicating
        that they were eligible for discard since the virtual
        circuit was created.  This occurs when the remote DTE
        sets the DE flag, or when in remote DTE's switch
        detects that the frame was received as Excess Burst
        data."
     REFERENCE
        "American National Standard T1.618-1991, Section 3.3.4"
     ::= { frCircuitEntry 18 }
 frCircuitSentDEs OBJECT-TYPE
     SYNTAX   Counter32
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "Number of frames sent to the network indicating that
        they were eligible for discard since the virtual
        circuit was created.   This occurs when the local DTE
        sets the DE flag, indicating that during Network
        congestion situations those frames should be discarded
        in preference of other frames sent without the DE bit
        set."
     REFERENCE
        "American National  Standard  T1.618-1991, Section
        3.3.4"
    ::= { frCircuitEntry 19 }
 frCircuitLogicalIfIndex OBJECT-TYPE
     SYNTAX  InterfaceIndex
     MAX-ACCESS read-create
     STATUS  current
     DESCRIPTION
        "Normally the same value as frDlcmiIfIndex, but
        different when an implementation associates a virtual
        ifEntry with a DLC or set of DLCs in order to associate
        higher layer objects such as the ipAddrEntry with a
        subset of the virtual circuits on a Frame Relay
        interface. The type of such ifEntries is defined by the
        higher layer object; for example, if PPP/Frame Relay is
        implemented, the ifType of this ifEntry would be PPP.
        If it is not so defined, as would be the case with an
        ipAddrEntry, it should be of type Other."
    ::= { frCircuitEntry 20 }
 frCircuitRowStatus OBJECT-TYPE
     SYNTAX   RowStatus
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
        "This object is used to create a new row or modify or
        destroy an existing row in the manner described in the
        definition of the RowStatus textual convention.
        Writable objects in the table may be written in any
        RowStatus state."
     ::= { frCircuitEntry 21 }
 --
 --  Error Table
 -- The table describing errors encountered on each Frame
 -- Relay Interface.
 frErrTable OBJECT-TYPE
     SYNTAX   SEQUENCE OF FrErrEntry
     MAX-ACCESS   not-accessible
     STATUS   current
     DESCRIPTION
        "A table containing information about Errors on the
        Frame Relay interface.  Discontinuities in the counters
        contained in this table are the same as apply to the
        ifEntry associated with the Interface."
     ::= { frameRelayDTE 3 }
 frErrEntry OBJECT-TYPE
     SYNTAX   FrErrEntry
     MAX-ACCESS   not-accessible
     STATUS   current
     DESCRIPTION
        "The error information for a single frame relay
        interface."
     INDEX { frErrIfIndex }
     ::= { frErrTable 1 }
 FrErrEntry ::=
     SEQUENCE {
         frErrIfIndex            InterfaceIndex,
         frErrType               INTEGER,
         frErrData               OCTET STRING,
         frErrTime               TimeStamp,
         frErrFaults             Counter32,
         frErrFaultTime          TimeStamp
 }
 frErrIfIndex OBJECT-TYPE
     SYNTAX   InterfaceIndex
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "The ifIndex Value of the corresponding ifEntry."
     ::= { frErrEntry 1 }
     frErrType OBJECT-TYPE
         SYNTAX   INTEGER    {
                     unknownError(1),
                     receiveShort(2),
                     receiveLong(3),
                     illegalAddress(4),
                     unknownAddress(5),
                     dlcmiProtoErr(6),
                     dlcmiUnknownIE(7),
                     dlcmiSequenceErr(8),
                     dlcmiUnknownRpt(9),
                     noErrorSinceReset(10)
                  }
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
 "The type of error that was last seen  on  this interface:
 receiveShort: frame was not long enough to allow
         demultiplexing - the address field was incomplete,
         or for virtual circuits using Multiprotocol over
         Frame Relay, the protocol identifier was missing
         or incomplete.
 receiveLong: frame exceeded maximum length configured for this
              interface.
 illegalAddress: address field did not match configured format.
 unknownAddress: frame received on a virtual circuit which was not
                 active or administratively disabled.
 dlcmiProtoErr: unspecified error occurred when attempting to
                interpret link maintenance frame.
 dlcmiUnknownIE: link maintenance frame contained an Information
                 Element type which is not valid for the
                 configured link maintenance protocol.
 dlcmiSequenceErr: link maintenance frame contained a sequence
                   number other than the expected value.
 dlcmiUnknownRpt: link maintenance frame contained a Report Type
                  Information Element whose value was not valid
                  for the configured link maintenance protocol.
 noErrorSinceReset: no errors have been detected since the last
                    cold start or warm start."
     ::= { frErrEntry 2 }
 frErrData OBJECT-TYPE
     SYNTAX   OCTET STRING (SIZE(1..1600))
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "An octet string containing as much of the error packet
        as possible.  As a minimum, it must contain the Q.922
        Address or as much as was delivered.  It is desirable
        to include all header and demultiplexing information."
     ::= { frErrEntry 3 }
 frErrTime OBJECT-TYPE
     SYNTAX   TimeStamp
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "The value of sysUpTime at which the error was
        detected."
     ::= { frErrEntry 4 }
 frErrFaults OBJECT-TYPE
     SYNTAX   Counter32
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "The number of times the interface has gone down since
        it was initialized."
     ::= { frErrEntry 5 }
 frErrFaultTime OBJECT-TYPE
     SYNTAX   TimeStamp
     MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
        "The value of sysUpTime at the time when the interface
        was taken down due to excessive errors.  Excessive
        errors is defined as the time when a DLCMI exceeds the
        frDlcmiErrorThreshold number of errors within
        frDlcmiMonitoredEvents. See FrDlcmiEntry for further
        details."
     ::= { frErrEntry 6 }
 --
 -- Frame Relay Trap Control
 frameRelayTrapControl OBJECT IDENTIFIER ::= { frameRelayDTE 4 }
 -- the following highly unusual OID is as it is for compatibility
 -- with RFC 1315, the SNMP V1 predecessor of this document.
 frameRelayTraps OBJECT IDENTIFIER ::= { frameRelayDTE 0 }
 frTrapState OBJECT-TYPE
     SYNTAX  INTEGER     { enabled(1), disabled(2) }
     MAX-ACCESS   read-write
     STATUS   current
     DESCRIPTION
        "This variable indicates whether the system produces
        the frDLCIStatusChange trap."
     DEFVAL { disabled }
     ::= { frameRelayTrapControl 1 }
 frTrapMaxRate OBJECT-TYPE
     SYNTAX  Integer32 (0..3600000)
     MAX-ACCESS   read-write
     STATUS   current
     DESCRIPTION
        "This variable indicates the number of milliseconds
        that must elapse between trap emissions.  If events
        occur more rapidly, the impementation may simply fail
        to trap, or may queue traps until an appropriate time."
     DEFVAL { 0 }        -- no minimum elapsed period is specified
     ::= { frameRelayTrapControl 2 }
 --  Data Link Connection Management Interface Related Traps
 frDLCIStatusChange NOTIFICATION-TYPE
     OBJECTS  { frCircuitState }
     STATUS      current
     DESCRIPTION
        "This trap indicates that the indicated Virtual Circuit
        has changed state.  It has either been created or
        invalidated, or has toggled between the active and
        inactive states.  If, however, the reason for the state
        change is due to the DLCMI going down, per-DLCI traps
        should not be generated."
 ::= { frameRelayTraps 1 }
 -- conformance information
 frConformance OBJECT IDENTIFIER ::= { frameRelayDTE 6 }
 frGroups      OBJECT IDENTIFIER ::= { frConformance 1 }
 frCompliances OBJECT IDENTIFIER ::= { frConformance 2 }
 -- compliance statements
 frCompliance MODULE-COMPLIANCE
     STATUS  current
     DESCRIPTION
        "The compliance statement "
     MODULE  -- this module
     MANDATORY-GROUPS { frPortGroup, frCircuitGroup }
     GROUP       frErrGroup
     DESCRIPTION
        "This optional group is used for debugging Frame Relay
        Systems."
     GROUP       frTrapGroup
     DESCRIPTION
        "This optional group is used for the management of
        asynchronous notifications by Frame Relay Systems."
     GROUP       frNotificationGroup
     DESCRIPTION
        "This optional group defines the asynchronous
        notifications generated by Frame Relay Systems."
     OBJECT      frDlcmiRowStatus
     MIN-ACCESS  read-only
     DESCRIPTION
        "Row creation is not required for the frDlcmiTable."
     OBJECT      frCircuitRowStatus
     MIN-ACCESS  read-only
     DESCRIPTION
        "Row creation is not required for the frCircuitTable."
     ::= { frCompliances 1 }
 frCompliance0 MODULE-COMPLIANCE
     STATUS  current
     DESCRIPTION
        "The compliance statement for objects and the trap
        defined in RFC 1315."
     MODULE  -- this module
     MANDATORY-GROUPS { frPortGroup0, frCircuitGroup0 }
     GROUP       frErrGroup0
     DESCRIPTION
        "This optional group is used for debugging Frame Relay
        Systems."
     GROUP       frTrapGroup0
     DESCRIPTION
        "This optional group is used for the management of
        asynchronous notifications by Frame Relay Systems."
     GROUP       frNotificationGroup
     DESCRIPTION
        "This optional group defines the asynchronous
        notifications generated by Frame Relay Systems."
     ::= { frCompliances 2 }
 -- units of conformance
 frPortGroup    OBJECT-GROUP
     OBJECTS {
               frDlcmiIfIndex, frDlcmiState, frDlcmiAddress,
               frDlcmiAddressLen, frDlcmiPollingInterval,
               frDlcmiFullEnquiryInterval, frDlcmiErrorThreshold,
               frDlcmiMonitoredEvents, frDlcmiMaxSupportedVCs,
               frDlcmiMulticast, frDlcmiStatus, frDlcmiRowStatus
            }
     STATUS  current
     DESCRIPTION
        "The objects necessary to control the Link Management
        Interface for a Frame Relay Interface as well as
        maintain the error statistics on this interface."
     ::= { frGroups 1 }
 frCircuitGroup    OBJECT-GROUP
     OBJECTS {
               frCircuitIfIndex, frCircuitDlci, frCircuitState,
               frCircuitReceivedFECNs, frCircuitReceivedBECNs,
               frCircuitSentFrames, frCircuitSentOctets,
               frCircuitReceivedFrames, frCircuitReceivedOctets,
               frCircuitCreationTime, frCircuitLastTimeChange,
               frCircuitCommittedBurst, frCircuitExcessBurst,
               frCircuitThroughput, frCircuitMulticast,
               frCircuitType, frCircuitDiscards,
               frCircuitReceivedDEs, frCircuitSentDEs,
               frCircuitLogicalIfIndex, frCircuitRowStatus
             }
     STATUS  current
     DESCRIPTION
        "The objects necessary to control the Virtual Circuits
        layered onto a Frame Relay Interface."
     ::= { frGroups 2 }
 frTrapGroup    OBJECT-GROUP
     OBJECTS { frTrapState, frTrapMaxRate }
     STATUS  current
     DESCRIPTION
        "The objects necessary to control a Frame Relay
        Interface's notification messages."
     ::= { frGroups 3 }
 frErrGroup    OBJECT-GROUP
     OBJECTS {
               frErrIfIndex, frErrType, frErrData, frErrTime,
               frErrFaults, frErrFaultTime
            }
     STATUS  current
     DESCRIPTION
        "Objects designed to assist in debugging Frame Relay
        Interfaces."
     ::= { frGroups 4 }
 frNotificationGroup NOTIFICATION-GROUP
     NOTIFICATIONS { frDLCIStatusChange }
     STATUS  current
     DESCRIPTION
        "Traps which may be used to enhance event driven
        management of the interface."
     ::= { frGroups 5 }
 frPortGroup0    OBJECT-GROUP
     OBJECTS {
               frDlcmiIfIndex, frDlcmiState, frDlcmiAddress,
               frDlcmiAddressLen, frDlcmiPollingInterval,
               frDlcmiFullEnquiryInterval, frDlcmiErrorThreshold,
               frDlcmiMonitoredEvents, frDlcmiMaxSupportedVCs,
               frDlcmiMulticast
            }
     STATUS  current
     DESCRIPTION
        "The objects necessary to control the Link Management
        Interface for a Frame Relay Interface as well as
        maintain the error statistics on this interface from
        RFC 1315."
     ::= { frGroups 6 }
 frCircuitGroup0    OBJECT-GROUP
     OBJECTS {
               frCircuitIfIndex, frCircuitDlci, frCircuitState,
               frCircuitReceivedFECNs, frCircuitReceivedBECNs,
               frCircuitSentFrames, frCircuitSentOctets,
               frCircuitReceivedFrames, frCircuitReceivedOctets,
               frCircuitCreationTime, frCircuitLastTimeChange,
               frCircuitCommittedBurst, frCircuitExcessBurst,
               frCircuitThroughput
             }
     STATUS  current
     DESCRIPTION
        "The objects necessary to control the Virtual Circuits
        layered onto a Frame Relay Interface from RFC 1315."
     ::= { frGroups 7 }
 frErrGroup0    OBJECT-GROUP
     OBJECTS {
               frErrIfIndex, frErrType, frErrData, frErrTime
            }
     STATUS  current
     DESCRIPTION
        "Objects designed to assist in debugging Frame Relay
        Interfaces from RFC 1315."
     ::= { frGroups 8 }
 frTrapGroup0    OBJECT-GROUP
     OBJECTS { frTrapState }
     STATUS  current
     DESCRIPTION
        "The objects necessary to control a Frame Relay
        Interface's notification messages from RFC 1315."
     ::= { frGroups 9 }
 END

Security Issues

Security issues for this MIB are entirely covered by the SNMP Security Architecture, and have not been expanded within the contents of this MIB.

Acknowledgments

This document was originally produced by the IP Over Large Public Data Networks (IPLPDN) Working Group, and has since been carried on in the PPP Working Group, sort of. Currently, the Ion Working Group is its host.

Special thanks to James Watt of Newbridge Networks for his fine suggestions and pastable text.

Authors' Addresses

Caralyn Brown Cadia Networks, Inc. 1 Corporate Dirve Andover, Massachusetts 01810 Telephone: +1 508 689 2400 x133 E-Mail: [email protected]

Fred Baker Cisco Systems 519 Lado Drive Santa Barbara, California 93111 Telephone +1 408 526 4257 E-Mail: [email protected]

10. References

[1] SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.,

    and S. Waldbusser, "Structure of Management Information
    for Version 2 of the Simple Network Management Protocol
    (SNMPv2)", RFC 1902, January 1996.

[2] McCloghrie, K., and M. Rose, Editors, "Management

    Information Base for Network Management of TCP/IP-based
    internets: MIB-II", STD 17, RFC 1213, Hughes LAN Systems,
    Performance Systems International, March 1991.

[3] Case, J., Fedor, M., Schoffstall, M., and J. Davin. " A

    Simple Network Management Protocol (SNMP)", STD 15, RFC
    1157, SNMP Research, Performance Systems International,
    MIT Lab for Computer Science, May 1990.

[4] SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.,

    and S. Waldbusser, "Protocol Operations for Version 2 of
    the Simple Network Management Protocol (SNMPv2)", RFC
    1905, January 1996.

[5] McCloghrie, K. and F. Kastenholz, "Evolution of the

    Interfaces Group of MIB-II", RFC 1573, Hughes LAN
    Systems, FTP Software, January 1994.

[6] T. Bradley, C. Brown, A. Malis, "Multiprotocol

    Interconnect over Frame Relay", RFC 1490, 07/26/1993.

[7] International Telegraph and Telephone Consultative

    Committee, "ISDN Data Link Layer Specification for Frame
    Mode Bearer Services", CCITT Recommendation Q.922, 19
    April 1991.

[8] American National Standard For Telecommunications -

    Integrated Services Digital Network - Frame Relay Bearer
    Service - Architectural Framework and Service
    Description, ANSI T1.606-1991, 18 June 1991.

[9] American National Standard For Telecommunications -

    Integrated Services Digital Network - Digital Subscriber
    Signalling System No. 1 - Signaling Specification for
    Frame Relay Bearer Service, ANSI T1.617-1991, 18 June
    1991.

[10] American National Standard For Telecommunications -

    Integrated Services Digital Network - Core Aspects of
    Frame Protocol for Use with Frame Relay Bearer Service,
    ANSI T1.618-1991, 18 June 1991.